384 research outputs found

    A Vision-Based Technique for Lay Length Measurement of Metallic Wire Ropes

    Get PDF
    The lay length of metallic wire ropes is an important dimensional quantity whose analysis is useful to highlight rope deformations due to distributed damages. This paper describes a measurement system that is based on a video camera and on an offline processing algorithm. The camera acquires an image sequence of the running rope; then, an image processing algorithm extracts the rope contour and measures both the distance among rope strands and the whole distance covered by the rope during the test. A mathematical model of the rope contour has been developed and employed to test the proposed algorithm with simulated data. Field tests have been carried out with the proposed system on a working aerial cableway using a general-purpose camer

    Intima-Media Thickness: Setting a Standard for a Completely Automated Method of Ultrasound Measurement

    Get PDF
    The intima - media thickness (IMT) of the common carotid artery is a widely used clinical marker of severe cardiovascular diseases. IMT is usually manually measured on longitudinal B-Mode ultrasound images. Many computer-based techniques for IMT measurement have been proposed to overcome the limits of manual segmentation. Most of these, however, require a certain degree of user interaction. In this paper we describe a new completely automated layers extraction (CALEXia) technique for the segmentation and IMT measurement of carotid wall in ultrasound images. CALEXia is based on an integrated approach consisting of feature extraction, line fitting, and classification that enables the automated tracing of the carotid adventitial walls. IMT is then measured by relying on a fuzzy K-means classifier. We tested CALEXia on a database of 200 images. We compared CALEXia performances to those of a previously developed methodology that was based on signal analysis (CULEXsa). Three trained operators manually segmented the images and the average profiles were considered as the ground truth. The average error from CALEXia for lumen - intima (LI) and media - adventitia (MA) interface tracings were 1.46 ± 1.51 pixel (0.091 ± 0.093 mm) and 0.40 ± 0.87 pixel (0.025 ± 0.055 mm), respectively. The corresponding errors for CULEXsa were 0.55 ± 0.51 pixels (0.035 ± 0.032 mm) and 0.59 ± 0.46 pixels (0.037 ± 0.029 mm). The IMT measurement error was equal to 0.87 ± 0.56 pixel (0.054 ± 0.035 mm) for CALEXia and 0.12 ± 0.14 pixel (0.01 ± 0.01 mm) for CULEXsa. Thus, CALEXia showed limited performance in segmenting the LI interface, but outperformed CULEXsa in the MA interface and in the number of images correctly processed (10 for CALEXia and 16 for CULEXsa). Based on two complementary strategies, we anticipate fusing them for further IMT improvement

    Rough Set Based Approach for IMT Automatic Estimation

    Get PDF
    Carotid artery (CA) intima-media thickness (IMT) is commonly deemed as one of the risk marker for cardiovascular diseases. The automatic estimation of the IMT on ultrasound images is based on the correct identification of the lumen-intima (LI) and media-adventitia (MA) interfaces. This task is complicated by noise, vessel morphology and pathology of the carotid artery. In a previous study we applied four non-linear methods for feature selection on a set of variables extracted from ultrasound carotid images. The main aim was to select those parameters containing the highest amount of information useful to classify the image pixels in the carotid regions they belong to. In this study we present a pixel classifier based on the selected features. Once the pixels classification was correctly performed, the IMT was evaluated and compared with two sets of manual-traced profiles. The results showed that the automatic IMTs are not statistically different from the manual one

    Motion Artifact Reduction in Breast Dynamic Infrared Imaging

    Get PDF
    Dynamic infrared imaging is a promising technique in breast oncology. In this study a QWIP infrared camera is used to acquire a sequence of consecutive thermal images of the patient's breast for 10 s. Information on the local blood perfusion is obtained from the spectral analysis of the time series at each image pixel. Due to respiratory and motion artifacts, the direct comparison of the temperature values that a pixel assumes along the sequence becomes difficult. In fact, the small temperature changes due to blood perfusion, of the order of 10-50 mK, which constitute the signal of interest in the time domain, are superimposed onto large temperature fluctuations due to the subject's motion, which represent noise. To improve the time series signal-to-noise ratio, and, as a consequence, enhance the specificity and sensitivity of the dynamic infrared examination, it is important to realign the thermal images of the acquisition sequence thus reducing motion artifacts. In a previous study we demonstrated that a registration algorithm based on fiducial points is suitable to both clinical applications and research, when associated with a proper set of skin markers. In this paper, we quantitatively evaluate the performance of different marker sets by means of a model that allows for estimating the signal-to-noise ratio increment due to registration, and we conclude that a 12-marker set is a good compromise between motion artifact reduction and the time required to prepare the patien

    Electron-hole localization in coupled quantum dots

    Full text link
    We theoretically investigate correlated electron-hole states in vertically coupled quantum dots. Employing a prototypical double-dot confinement and a configuration-interaction description for the electron-hole states, it is shown that the few-particle ground state undergoes transitions between different quantum states as a function of the interdot distance, resulting in unexpected spatial correlations among carriers and in electron-hole localization. Such transitions provide a direct manifestations of inter- and intradot correlations, which can be directly monitored in experiments.Comment: 11 pages, 3 figures (eps), LaTeX 2e. To appear in PRB (Rapid Communication

    Evaluation of time-series registration methods in dynamic area telethermometry for breast cancer detection

    Get PDF
    Automated motion reduction in 3D dynamic infrared imaging is on demand in many applications. Few methods for registering time-series dynamic infrared frames have been proposed. Almost all such methods are feature based algorithms requiring manual intervention. We apply different automated registration methods based on spatial displacement to 11 datasets of Breast Dynamic Infrared Imaging (DIRI) and evaluate the results in terms of both the image similarity and anatomical consistency of the transformation. The aim is to optimize the registration strategy for breast DIRI in order to improve the spectral analysis of temperature modulation; thus facilitating the acquisition procedure in a Dynamic Area Telethermometry framework. The results show that symmetric diffeomorphic demons registration outperforms both warped frames similarity and smoothness of deformation fields; hence proving effective for time-series dynamic infrared registratio

    Field-controlled suppression of phonon-induced transitions in coupled quantum dots

    Full text link
    We calculate the longitudinal-acoustic phonon scattering rate for a vertical double quantum dot system with weak lateral confinement and show that a strong modulation of the single-electron excited states lifetime can be induced by an external magnetic or electric field. The results are obtained for typical realistic devices using a Fermi golden rule approach and a three-dimensional description of the electronic quantum states.Comment: REVTex4 class, 6 pages, 3 figures, to be published in Applied Physics Letter

    Time and time-frequency analysis of near-infrared signals for the assessment of ozone autohemotherapy long-term effects in multiple sclerosis

    Get PDF
    Ozone autohemotherapy is an emerging therapeutic technique that is gaining increasing importance in treating neurological disorders. A validated and standard methodology to assess the effect of such therapy on brain metabolism and circulation is however still lacking. We used a near-infrared spectroscopy system (NIRS) to monitor the cerebral oxygenation of 9 subjects: 4 remitting-relapsing multiple sclerosis (MS) sufferers and 5 controls. Subjects were tested before, during, and after ozone autohemotherapy. We monitored the concentration changes in the level of oxygenated and deoxygenated haemoglobin, and in the level of the Cytochrome-c-oxidase (CYT-c). From the time and time-frequency analysis of the NIRS signals we extracted 128 variables, which were used to characterize the metabolic brain pattern during the therapy. We showed that by using only 7 NIRS variables out of 128 it is possible to characterize the metabolic brain pattern of the two groups of subjects. The MS subjects showed a marked increase of the CYT-c activity and concentration about 40 minutes after the end of the autohemotherapy, possibly revealing a reduction of the chronic oxidative stress level typical of MS sufferers. From a technical point of view, this preliminary study showed that NIRS could be useful to show the effects of ozone autohemotherapy at cerebral level, in a long term monitoring. The clinical result of this study is the quantitative measurement of the CYT-c level changes in MS induced by ozone autohemotherap
    • 

    corecore